Curtition
The
Accordion
Door
Specialists
|
|

CURTITION OPERABLE
PARTITIONS
FIRST STEP--CEILING GUARD
AND TRACK
- Track and ceiling guard may be installed prior to
receipt of door, depending upon your requirements
- Accurately measure the finished length of the opening
for the track, from upright vertical to upright vertical.
- Track and ceiling guard are supplied in standard 10'
sections, plus the amount required to complete the
finished door length. The last section will be pre-cut
longer than required (to the next 5' )and will need to be
trimmed to length.
INSTALLATION
- Track may be installed separately or with ceiling
guard. If ceiling guard is to be installed separately,
measure length as in step 2. (above). Punch or pre-drill
holes where fasteners are to be attached. Fastener
spacing should be no more than 24" apart.
(Note: If track is to be installed with ceiling
guard, track joints should come together at different
points than ceiling guard joints. Use either the
trimmed length of ceiling guard with a standard length
of track for the first section, or vice versa.)
- Attach only the first length of ceiling guard to the
anchor end of the header, using 2" #8 screws (provided).
(Tip: If ceiling guard has a rolled edge with
protective tape,remove the tape from the rolled edge
only, before anchoring the ceiling guard to the header.
Tape on the rolled edge (backside) of ceiling guard is
very difficult to remove after installation.)
- If ceiling guard and track are being installed
together, place one section of track inside a different
length section of ceiling guard and mark position of
pre-drilled track screw holes on the ceiling guard.
- Punch or pre-drill ceiling guard to match track holes
for fasteners.
- Lift track inside ceiling guard to mounting position
on header and attach with 2" #8 screws (provided).
Note: Joints where track sections meet must be in
alignment, smooth and tight).
(Tip: It will be much easier to slide the track
rollers onto the first section of track if you anchor
the track at one end (1/3 to 1/2 its length) and allow
the other end to hang below the header. Rollers can
then be pushed onto the track with the weight of the
door resting vertically on the floor, no lifting
required)
If track is to be installed without ceiling guard, attach
one section as above, using 2" #8 screws (provided).
(Note: Exposed installations, using any 3-way or 4-way
floating posts will require you to trim the joining track 5"
short of the main track centerline in order to allow
sufficient space for the doors to pass. Place a screw stop
in the track to prevent travel beyond the end.)
UNPACKING THE
DOOR
- Carefully remove the door from its shipping
container, still in its cardboard wrapping, and lay it on
the clean floor, at right angles to the installed track,
taking special carenot to soil the door cover. The anchor
post should face the side of the opening to which the
post will be anchored. Wheels should face away from the
opening. (Note: This is not necessary on doors with
"movable post" option since there is no anchor post
end.)
- Carefully remove packing straps and roll back
the protective cardboard covering to expose the door.
Leave cardboard underneath the door.
- Inspect the door for shipping damage. If problems are
noted, call Curtition Customer Service at (262) 882-1233
for assistance.
HANGING THE DOOR
- Carefully lift the top (roller end) of the door to
chest height and "walk it" up to vertical. If the door is
over 10' in height be sure to have a person on each side
for added safety during handling. There should also be an
additional person on each side for every 10' of
horizontal length. (Note: In the vertical position the
door will settle somewhat on its bottom so some lifting
may be required to raise the rollers to track level. [See
section 5. under "Ceiling Guard and Track Installation,
above])
- Feed the rollers onto the single section of track,
being certain that no rollers are missed !
- Slide the door toward the wall or attachment end of
the track.
- Attach remaining track sections to header or ceiling
guard. Be certain the track and ceiling guard joints
are in alignment.
ATTACHMENT TO THE
WALL
- After the door is hung, scribe a vertical line on
both walls or attachment points, plumb with the track
centerline.
- An aluminum, vinyl covered "U"- Channel is provided
as a wall mount or anchor for the VL series doors. The
door latch end piece of channel has a felt lining. The
channel for the anchor end
has no felt lining. (Note: The Mark X
and Mark XX Series sight divider doors will not have a
latch end channel)
- Place channels against their respective walls and
align the channel centerline with the vertical centerline
scribed on the wall.
- Anchor channels to walls using 2" #8 screws
(provided).
- Insert the wall anchor post into its channel. Drill
holes through the anchor post and channel and secure both
to wall or jamb strip using 5/8" #4 screws (provided).
(Note: The latch hook receiver has been pre-attached
to the female jamb strip).
- Place jamb strip inside the felt lined channel and
anchor in place, using 1" #6 screws (provided).
- For Mark X and Mark XX Sight Divider doors, anchor
the female jamb strip against the latch end wall using 1"
#6screws provided.
LATCH RECEIVER
The latch hook receiver can be adjusted
vertically to fit the nose slot of the latch housing.
- Loosen the set screws directly above and below the
latch receiver loop.
- Slide the door leading edge up against the latch
channel and align the loop with the midpoint of the latch
hook.
- When in alignment, tighten the set screws.
SWEEP STRIPS
There may, in some situations, be variation in
floor to ceiling height along the length of the door. The
door has been fabricated to the shorter end of the variance
range, and extendible sweep strips may have been added. If
this is the case,
- Carefully trim the sweep strips, using a sharp knife
or cutting blade, so that they gently contact the floor
across the full width of the opening.